FABRICATION BENEFITS
- FW 80+ XR successfully tested in accordance with ISO16933 to EXV 15 (D)
- FW 60+ XR successfully tested to EXV 19 (D)
- Tested unit dimensions: 3485 x 3210 mm
- Max. tested glass sizes: 1545 x 1980 mm
- Excellent thermal insulation with Uf values of up to 1.2 W/(m2k)
- Extended area of application based on calculations
- System approval for Schüco FW 80+ XR available as a summary of the relevant system features
TECHNICAL INFOS
- System basic depth
-
- 105 mm
- Min. face width
-
- 80 mm
- Uf value of frame (≥)
-
- 1.2 W/(m²·K)
- Max. glass/panel thickness
-
- 44 mm
- Air permeability
-
- AE
- Watertightness
-
- RE 1200
- Burglar resistance
-
- Up to RC2
- Wind load resistance
-
- 2.0/3.0 [kN/m²]
- Security system
-
- Ja
- Min.-max. glass/panel thickness
-
- 24…44 mm
- Impact resistance
-
- Class 5
- Blast resistance
-
- Yes
- SYSTEM / MATERIAL
-
- Aluminium
- FUNCTIONS
-
- Blast resistance
TEST DOCUMENTS
Type of document |
|
Doc. no. / Download | |||||||||
Classification report |
|
13-001776-PR01 (pdf, 4 MB) | |||||||||
Technical approval |
|
Z-14.4-452_en (pdf, 4 MB) | |||||||||
Expert statement |
|
13-001776-PR02 (pdf, 3 MB) |
BROCHURES
-
Aluminium
Schüco blast resistance
Contents