Sliding System ASS 39 PD.NI

Non-insulated sliding system with Panorama Design – can be used flexibly in warm climate zones and for interiors

Highly transparent solutions for areas without thermal insulation requirements. With floor-to-ceiling glazing, the Schüco ASS 39 PD.NI (Panorama Design Non-Insulated) sliding system ensures visually flowing transitions in the interior and to the outside.

The extraordinary sliding system with the option of concealed, handle-free operation in the interlock section or elegant continuous pull grip captivates with its clear, homogeneous appearance.

The opening 90° corners are an attractive additional opening type which expands the architectural possibilities.

A new locking point, the optional locking feature for the system from the inside and outside, as well as an integrated flyscreen, ensure a high level of security and comfort.

Fabrication without bonding and the reduced number of individual components ensure easier, faster and therefore more reliable fabrication of the system.

หมวดหมู่:

Fabrication benefits

  • Simple and fast cleaning and maintenance of the rollers without removing the vent
  • Easy to fabricate individual components
  • Reduced number of individual components ensures easier and thus more reliable fabrication of the system
  • Easier, faster fabrication because no bonding is necessary
  • Butt joint or mitre joint fabrication

Technical information

System basic depth39 mm
Max. vent width3000 mm
Max. vent height3500 mm
Max. vent weight350 kg
Min. face width37 mm
Max. glass/panel thickness32 mm
Uw value of window (≥)1.9 W/(m²·K)
Total basic depth107 mm
Min. system basic depth107 mm
Min.-max. system basic depth107…162 mm
Width of vent frame39 mm
Min. vent width1000 mm
Min.-max. vent width1000…3000 mm
Min. vent height2000 mm
Max. unit width18000 mm
Max. unit height3500 mm
Outer frame face width0 mm
Vent frame face width0 mm
Min. face width of interlocking section37 mm
Min. face width of mullion37 mm
Min.-max. face width of mullion37 mm
Min. face width of meeting stile90 mm
Min.-max. face width of meeting stile90 mm
Face width of fixed glazing0 mm
Min.-max. glass/panel thickness6…32 mm
Threshold height< 12,5
Area of applicationInternal use, External use, Commercial projects
Meeting stile designYes
Number of vents6
Fixed lights/identified ventsYes
Number of tracksDouble track, Triple track
Track materialAluminium
Surface finishesPowder, Anodised, Paint
Concealed lockYes
Concealed drive systemNo
Operating forcesClass 1
Operating typemanual
Opening typeType 2A, Type 2A/1, Type 2B, Type 2C, Type 2D, Type 2D/1, Type 2D/1 – 90° A, Type 3E, Type 3E/1, Type 3F, Type 3F – 90° A
Mechanical strengthClass 4
Proof of durabilityClass 3
Air permeabilityClass 3
Wind load resistanceClass C2 / B2
WatertightnessClass 7A
Security glazingYes
Colour-independentYes

Documentation

[Ba] Schüco ASS 39 PD.NI

View online

[Ba1] Schüco ASS 39 PD.NI

View online

[Ba2] Schüco ASS 39 PD.NI

View online

Schüco Sliding Systems ASS, Basic Depth ≤ 50 mm – Architect Information 17

View onlineDownload

CAD data

Planning principles

View online

Test documents

1-10 of 15
Document type Test type Result Classification Document no. / Download
Prüfzeugnis Luftdurchlässigkeit
Schlagregendichtheit
Windwiderstandsfähigkeit
Bedienungskraft
Klasse 3
Klasse 6A
Klasse C2/B2
Klasse 1
View onlineDownload (pdf, 1.0 MB)
Prüfzeugnis Bedienungskraft
Dauerlaufprüfung
Klasse 1
Klasse 3
View onlineDownload (pdf, 520.4 KB)
Prüfzeugnis Luftdurchlässigkeit
Schlagregendichtheit
Windwiderstandsfähigkeit
Bedienungskraft
Klasse 3
Klasse 5A
Klasse C2/B2
Klasse 1
View onlineDownload (pdf, 1.0 MB)
Prüfzeugnis Pendelschlagversuch Klasse 4 View onlineDownload (pdf, 453.5 KB)
Prüfzeugnis Luftdurchlässigkeit
Schlagregendichtheit
Windwiderstandsfähigkeit
Bedienungskraft
Vertikallast
Klasse 3
Klasse 5A
Klasse C2/B2
Klasse 1
Klasse 4
View onlineDownload (pdf, 173.8 KB)
Prüfzeugnis Einbruchhemmung RC 1 N View onlineDownload (pdf, 161.4 KB)
Prüfbericht Luftdurchlässigkeit
Schlagregendichtheit
Schlagregendichtheit
Widerstand gegen Windlast
50
270
570
1820
Superior
Superior
Intermediate
View onlineDownload (pdf, 1.7 MB)
Prüfbericht Luftdurchlässigkeit
Schlagregendichtheit
Schlagregendichtheit
Widerstand gegen Windlast
50
60
480
1820
Superior
Superior
Intermediate
View onlineDownload (pdf, 1.5 MB)
Prüfbericht Luftdurchlässigkeit
Schlagregendichtheit
Schlagregendichtheit
Widerstand gegen Windlast
50
120
270
1480
Superior
Superior
Intermediate
View onlineDownload (pdf, 1.4 MB)
Prüfzeugnis Luftdurchlässigkeit
Schlagregendichtheit
Schlagregendichtheit
Widerstand gegen Windlast
50
60
480
1820
Superior
Superior
Intermediate
View onlineDownload (pdf, 596.7 KB)
1-10 of 15

Brochures

Schüco ASS 39 PD.NI

View onlineDownload

%d bloggers like this: